Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
EClinicalMedicine ; 60: 102031, 2023 Jun.
Article in English | MEDLINE | ID: covidwho-20245458

ABSTRACT

Background: Venous thromboembolism is a major complication of coronavirus disease 2019 (COVID-19). We hypothesized that a weight-adjusted intermediate dose of anticoagulation may decrease the risk of venous thromboembolism COVID-19 patients. Methods: In this multicenter, randomised, open-label, phase 4, superiority trial with blinded adjudication of outcomes, we randomly assigned adult patients hospitalised in 20 French centers and presenting with acute respiratory SARS-CoV-2. Eligible patients were randomly assigned (1:1 ratio) to receive an intermediate weight-adjusted prophylactic dose or a fixed-dose of subcutaneous low-molecular-weight heparin during the hospital stay. The primary outcome corresponded to symptomatic deep-vein thrombosis (fatal) pulmonary embolism during hospitalization (COVI-DOSE ClinicalTrials.gov number: NCT04373707). Findings: Between May 2020, and April 2021, 1000 patients underwent randomisation in medical wards (noncritically ill) (80.1%) and intensive care units (critically ill) (19.9%); 502 patients were assigned to receive a weight-adjusted intermediate dose, and 498 received fixed-dose thromboprophylaxis. Symptomatic venous thromboembolism occurred in 6 of 502 patients (1.2%) in the weight-adjusted dose group and in 10 of 498 patients (2.1%) in the fixed-dose group (subdistribution hazard ratio, 0.59; 95% CI, 0.22-1.63; P = 0.31). There was a twofold increased risk of major or clinically relevant nonmajor bleeding: 5.9% in the weight-adjusted dose group and 3.1% in the fixed-dose group (P = 0.034). Interpretation: In the COVI-DOSE trial, the observed rate of thromboembolic events was lower than expected in patients hospitalized for COVID-19 infection, and the study was unable to show a significant difference in the risk of venous thromboembolism between the two low-molecular-weight-heparin regimens. Funding: French Ministry of Health, CAPNET, Grand-Est Region, Grand-Nancy Métropole.

2.
PLoS One ; 18(4): e0284748, 2023.
Article in English | MEDLINE | ID: covidwho-2300386

ABSTRACT

BACKGROUND: Lung point-of-care ultrasonography (L-POCUS) is highly effective in detecting pulmonary peripheral patterns and may allow early identification of patients who are likely to develop an acute respiratory distress syndrome (ARDS). We hypothesized that L-POCUS performed within the first 48 hours of non-critical patients with suspected COVID-19 would identify those with a high-risk of worsening. METHODS: POCUSCO was a prospective, multicenter study. Non-critical adult patients who presented to the emergency department (ED) for suspected or confirmed COVID-19 were included and had L-POCUS performed within 48 hours following ED presentation. The lung damage severity was assessed using a previously developed score reflecting both the extension and the intensity of lung damage. The primary outcome was the rate of patients requiring intubation or who died within 14 days following inclusion. RESULTS: Among 296 patients, 8 (2.7%) met the primary outcome. The area under the curve (AUC) of L-POCUS was 0.80 [95%CI:0.60-0.94]. The score values which achieved a sensibility >95% in defining low-risk patients and a specificity >95% in defining high-risk patients were <1 and ≥16, respectively. The rate of patients with an unfavorable outcome was 0/95 (0%[95%CI:0-3.9]) for low-risk patients (score = 0), 4/184 (2.17%[95%CI:0.8-5.5]) for intermediate-risk patients (score 1-15) and 4/17 (23.5%[95%CI:11.4-42.4]) for high-risk patients (score ≥16). In confirmed COVID-19 patients (n = 58), the AUC of L-POCUS was 0.97 [95%CI:0.92-1.00]. CONCLUSION: L-POCUS performed within the first 48 hours following ED presentation allows risk-stratification of patients with non-severe COVID-19.


Subject(s)
COVID-19 , Adult , Humans , COVID-19/diagnostic imaging , Point-of-Care Systems , Prospective Studies , Ultrasonography , Emergency Service, Hospital , Risk Assessment
5.
Thromb Haemost ; 122(11): 1888-1898, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-1684157

ABSTRACT

OBJECTIVE: D-dimer measurement is a safe tool to exclude pulmonary embolism (PE), but its specificity decreases in coronavirus disease 2019 (COVID-19) patients. Our aim was to derive a new algorithm with a specific D-dimer threshold for COVID-19 patients. METHODS: We conducted a French multicenter, retrospective cohort study among 774 COVID-19 patients with suspected PE. D-dimer threshold adjusted to extent of lung damage found on computed tomography (CT) was derived in a patient set (n = 337), and its safety assessed in an independent validation set (n = 337). RESULTS: According to receiver operating characteristic curves, in the derivation set, D-dimer safely excluded PE, with one false negative, when using a 900 ng/mL threshold when lung damage extent was <50% and 1,700 ng/mL when lung damage extent was ≥50%. In the derivation set, the algorithm sensitivity was 98.2% (95% confidence interval [CI]: 94.7-100.0) and its specificity 28.4% (95% CI: 24.1-32.3). The negative likelihood ratio (NLR) was 0.06 (95% CI: 0.01-0.44) and the area under the curve (AUC) was 0.63 (95% CI: 0.60-0.67). In the validation set, sensitivity and specificity were 96.7% (95% CI: 88.7-99.6) and 39.2% (95% CI: 32.2-46.1), respectively. The NLR was 0.08 (95% CI; 0.02-0.33), and the AUC did not differ from that of the derivation set (0.68, 95% CI: 0.64-0.72, p = 0.097). Using the Co-LEAD algorithm, 76 among 250 (30.4%) COVID-19 patients with suspected PE could have been managed without CT pulmonary angiography (CTPA) and 88 patients would have required two CTs. CONCLUSION: The Co-LEAD algorithm could safely exclude PE, and could reduce the use of CTPA in COVID-19 patients. Further prospective studies need to validate this strategy.


Subject(s)
COVID-19 , Pulmonary Embolism , Humans , Fibrin Fibrinogen Degradation Products , Lung , Prospective Studies , Retrospective Studies